RULES ,
REGULATIONS & SCHEDULE OF CHARGES FOR TESTING SAMPLES TO
BE REVISED FROM : 01/12/2006 |
|
|
1. |
Sample for testing will be accepted during office
working hours on all week days, except on holidays, working hours are :
Monday to Saturday - 9.00 a.m. to 5.30 p.m. |
|
2. |
Test charges are payable strictly in advance at
the time of submitting the samples. In any case, no test will be started till
payment is received. Cheques are to be drawn in favor of “WOOL RESEARCH ASSOCIATION”. |
|
3. |
Sufficient quantity of samples, as shown in the
schedule of charges for tests , should be submitted alongwith an application
for requisite tests |
|
4. |
The Test Report shall be based on Samples
as received In their own interest, the clients should make it certain
that the samples represent the bulk.Samples for moisture estimation will be
accepted only in airtight packing and test report will bear the remark as received
Alternatively, WRA may depute their person subject to circumstances
prevailing itself to draw samples and seal them in airtight packing. |
|
5. |
If specifically requested, testing house staff
will be deputed to draw the samples. special charges for samples drawing will
be decided by the association in each case and these also will have to be
paid in advance. |
|
6. |
Samples must be clearly
'MARKED' and 'LABELLED' at the time of submitting them. |
|
7. |
If samples are to be tested to some definite
specifications,instructions in this regard in writing must be submitted
alongwith the samples |
|
8. |
Sample for test will not be accepted if it is felt
that their condition is such as to render the results unreliable one if the
size is below the recommended one. |
|
9. |
Tests not mentioned in the schedule will be
carried out, if necessary equipment is available; charges for such case will
be decided by the association. |
|
10. |
In the normal course, only two copies of the Test
Report will be supplied Additional copies will be supplied at Rs. 40/- per copy |
|
11. |
In all matters regarding acceptance, rejection, priority in testing, etc. the decision of the association will be final |
|
12. |
The above rules & regulations and the schedule
of charges are subject to change without previous notice. |
|
13. |
All tests will be undertaken subject to the
condition that no legal responsibility is attached to the association for
test reports issued and findings given therein. |
|
14. |
Normally, test reports will be issued within 15 days of receipt of samples,
however, if the number of samples and the number of tests to be carried out
are large, WRA Test House has the authority to decide the period of testing. |
|
15. |
On Party's request the resting of samples will be
undertaken on priority or urgent basis, on payment of one and half times the
NORMAL charges. In case of urgent samples if the reports are delayed
the charges will be 'NORMAL'. |
|
16. |
The WRA Test House will take all possible care as
regards samples received for testing; however, it will not be responsible for
any loss or damage which may occur. The sample will be preserved for ONE
MONTH after completing the test. |
|
17. |
All samples or goods must be delivered to and
removed from the association by the party on whose behalf the tests will be
carried out, but they may be forwarded by post /courrier at the party's
expense and risk. The association assumes no responsibility for delay or
damage or loss of samples or reports sent by post. |
|
18. |
The contents of test reports and correspondence
with clients will be kept strictly confidential. |
|
19. |
The material remaining after test will not be
returned unless a specific request is made by the party at the time of
submitting the sample for test. |
|
20. |
Special consultancy charges will also include type
of work , work involved, man-hours spent and procurement of raw material, if
any. |
Fibre / Sliver Testing
|
||||||
|
Ref. No. |
Test
Description |
Method |
Quantity
Required |
Charges |
||
|
1. |
Moisture % |
IWTO 13/BIS |
0.5 kg |
200 |
||
|
2. |
Invoice Weight |
IWTO 33 /34 |
0.5 kg |
600 |
||
|
3. |
Clean Wool Fibre
Content |
IWTO 19/BIS |
1.0 kg. |
700 |
||
|
4. |
Vegetable Matter |
IWTO 19 |
0.5 kg |
170 |
||
|
5. |
Wool Base |
IWTO 19 |
1.0 kg |
700 |
||
|
6. |
Ashing Of Loose
Wool |
IWTO 19 |
|
300 |
||
|
7. |
Black Fibre Content |
IWTO (E) 13 |
|
200 |
||
|
8. |
Colour |
IWTO/ / NZ |
|
250 |
||
|
9. |
Fibre Fineness (Micron ) Air Flow Method |
IWTO 28 |
0.5 meter |
200 |
||
|
10. |
OFDA |
IWTO 47 |
0.5 kg |
230 |
||
|
11. |
Projection
Microscope |
IWTO 8 |
0.5 kg |
300 |
||
|
12. |
Single Fibre Length
|
IWTO 5 |
0.5 kg |
220 |
||
|
13. |
Fibre Length of sliver / Top |
IWTO 16 |
5 meters |
250 |
||
|
14. |
Kemp Content
(Physical separation) |
|
280 gms |
160 |
||
|
15. |
Staple Length |
IWTO 30 |
0.5 kg |
200 |
||
|
16. |
Nep Count (Visual) |
IWTO 24 |
5 meters |
100 |
||
|
17. |
Staple Strength And
P.O.B. |
IWTO 30 |
.5 kg |
550 |
||
|
18. |
Residual
Grease(Soxlet) |
IWTO |
0.5 kg |
200 |
||
|
19. |
Denier Of Fibre |
|
0.5 meter |
200 |
||
|
20. |
Single Fibre
Strength INSTRON |
|
280 gms |
255 |
||
|
21. |
Sampling By Core Drill |
IWTO |
per bale |
100 |
||
|
22. |
Crimp |
|
25 gram |
100 |
||
|
23. |
Bundle Strength |
ASTM 1291 |
|
350 |
||
|
24. |
Evenness (U%) |
IWTO 18 |
|
200 |
||
|
Yarn
Testing |
||||||
|
24. |
Linear Density
(Count ) |
|
10 bobbins |
100 |
||
|
25. |
Twist &
Direction Of Twist |
IWTO 25 |
5 bobbins |
200 |
||
|
26. |
Fibre Fineness (Micron) Projection
Microscope |
IWTO 8 |
0.5 meter |
300 |
||
|
27. |
OFDA |
IWTO 47 |
0.5 meter |
230 |
||
|
28. |
Fibre Length Single Fibre
Measurement |
IWTO 5 |
10 bobbins |
250 |
||
|
29. |
Evenness(U%) (With
Imperfections For Single Yarn) |
IWTO 18 |
10 bobbins |
250 |
||
|
30. |
Yarn Hairiness |
|
10 bobbins / |
|||